AppliTOC™
Series of On-line TOC Analyzers
Total Organic Carbon analysis has been classified as a non-specific analysis method to determine the organic load in water. Its inherent accuracy and speed, combined with a low cost of ownership make it a preferred (standard) analysis method in many countries and industries. The AppliTOC™ Series of On-line TOC Analyzers have been field-tested for many years in a wide range of applications and environments to determine organic compounds in water matrices.
The standard Total Organic Carbon configuration of the AppliTOC™ is in fact a measure of the non purgeable organic carbon (NPOC), while the volatile carbon (VOC) and the purgeable carbon (POC) are stripped out and lost for analysis. Although all UV/persulfate TOC analyzers employ similar basic techniques, AppliTek has challenged the boundaries of this technology. AppliTOC™ uses an adapted version of the standard TOC method in accordance with standard methods USEPA 415.2, ISO 8245 and DIN-EN 1484, by finetuning the oxidation process and optimizing its core performance.
Special configurations
The so-called “True TOC” is a special configuration of the AppliTOC™ which is a 100% measure of all organic carbon in the sample, and applicable when the ordinary TOC configuration does not satisfy your needs.
For hazardous areas, a special enclosure in stainless steel is available with all necessary connections, special analytics and control units, designed and certified to fully meet ATEX or NEC 500 directives.
Analytical mainframe can be configured to Total Organic Carbon, True Total Organic Carbon or, Total Inorganic Carbon or Total Carbon
Smart features and add-on units reduce down-time and unnecessary checks substantially
Built-in carbon removal system for purifying instrument air
Unique range-specific solid state IR detectors with automatic zero calibration
Up to three (6) sampling points possible
Incorporated industrial PC with AppliTek controller software
Analysis method
Hot-aerosol UV / persulfate method
Measuring ranges
One single range, factory set:
0 – 5 mg C/L 0 – 500 mg C/L
0 – 10 mg C/L 0 – 1,000 mg C/L
0 – 20 mg C/L 0 – 5,000 mg C/L
0 – 100 mg C/L 0 – 10,000 mg C/L
Standard configuration
Total Organic Carbon as non purgeable organic carbon (NPOC)
Other configurations
Total Inorganic Carbon:
TIC + POC + VOC
Total Carbon:
TC = NPOC + POC + VOC + TIC
True TOC:
TOC = NPOC + POC + VOC ― TIC
Cycle time
6 – 12 minutes (depending on range)
Calibration
Automatic, free adjustable sequence
Validation
Automatic, free adjustable sequence
Cleaning
Automatic, free adjustable sequence